Spectrophotometer
Atomic Absorption Spectrophotometer
Wavelength Range–190-900nm
Background Correction– The S-H background correction capability at 1.8A better than 30 times.
Lamp Turret– 6
Wavelength Range–190-900nm
Background Correction– The D2 lamp background correction capability at 1A is better than 30 times.
Lamp Turret–4
Wavelength Range–190-900nm.
Background Correction– The D2 lamp background correction capability at 1A is better than 30 times.
Lamp Turret–2 lamps are powered simulataneously(one preheated).
Wavelength Range– 190-900nm.
Background Correction– The D2 lamp background correction capability at 1A is better than 30 times.The S-H background correction capability at 1.8A is better than 30 times.
Lamp Turret– 6-lamp turret (Two high performance HCLs can be mounted on the turret to increase the sensitivity)
Wavelength Range– 190-900nm.
Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. T
Lamp Number– 4 lamps.
Wavelength Range– 190-900nm.
Zeeman background correction technology
Lamp Turret– Automatic 8 x 2 lamp turret (Two high performance hollow cathode lamps can be mounted on each turret)
Flame mode- 0.2, 0.4, 0.8, 1.6mm
Graphite furnace mode- 0.2, 0.4, 1.2mm
Wavelength Range– 190-900nm
Background Correction– Deuterium lamp 1.0 Abs
Burner– Titanium alloy burner
Atomic Emission Spectrophotometer
Spectrum range
– 175-450 nm
Maximum number of channel – 36
Power supply – AC 220v ±10% 50 Hz
Input power – 1.0 kVA
Atomic Fluorescence Spectrophotometer
Techniques with independent intellectual property.
Environmental protection type Atomic Fluorescence Spectrophotometer with "High efficiency Hg-elimination Technique" can decontaminate Hg pollution in lab environment efficiently and protect analyst’s health.
Determination of Hg, As, Sb, Bi, Se, Te, Pb, Sn, Ge, Zn and Cd.
Quartz atomizer with "full-ceramics infrared heating temperature control" technique has super long lifetime.
“Low-temperature atomic Argon-Hydrogen flame auto-ignition" can improve the analysis sensitivity of elements to be determined and reduce memory effect in large degree.
FTIR Spectrometers
Spectral Range – 7800cm-1 to 400cm-1
Resolution – Better than 0.85cm-1
Scanning Speed – 0.2 cm-1/s ~ 0.25cm-1/s automatically optimized for detector type or manually adjustable for specific application
Detector – DTGS; Optional: MCT
Spectral Range – 7800cm-1 to 400cm-1
Resolution – Better than 0.5cm-1
Scanning Speed – 0.2 cm-1/s ~ 0.25cm-1/s automatically optimized for detector type or manually adjustable for specific application
Detector – DTGS; Optional: MCT
UV-Visible Double Beam Spectrophotometer
Optical System- Double Beam
Wavelength Range- 190 ~1100 nm
Spectral Bandwidth- 2 nm (5nm, 4nm, 1nm, 0.5nm optional)
Detector- Silicon photo diode
Photometric Accuracy- ±0.3%T (0~100%T); ±0.002A (0~1A)
Optical System- Double Beam
Wavelength Range- 190~900nm
Spectral Bandwidth- 0.1nm, 0.2nm, 0.5nm, 1.0nm, 2.0nm
Detector- Photomultiplier
Photometric Accuracy- ± 0.3%T (0~100%T), ± 0.002A
(0~0.5A), ± 0.004A (0.5A~1A)
Optical System- Double Beam
Wavelength Range- 190 - 1100nm
Spectral Bandwidth- 2nm (fixed slit)
Detector- Silicon photodiode
Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)
Optical System- Double Beam
Wavelength Range- 190 - 1100nm
Spectral Bandwidth- 0.5, 1, 2, 5nm (Variable slit)
Detector- Silicon photodiode
Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)
Optical System- Double Beam
Wavelength Range- 190 - 900nm
Spectral Bandwidth- 0.5, 1, 2, 5nm (Variable slit)
Detector- Silicon photodiode
Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)
UV-Visible Single Beam Spectrophotometer
Optical System- Single Beam
Wavelength Range- 190 - 1100nm
Spectral Bandwidth- 2nm (5nm, 4nm, 1nm, 0.5nm optional)
Detector- Silicon photodiode
Photometric Accuracy- 0.3%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)
Optical System- Single Beam
Wavelength Range- 190 - 1100nm
Spectral Bandwidth- 2nm (5nm, 1nm optional)
Detector- Silicon photo-diode
Photometric Accuracy- 0.5%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)
Optical System- Single Beam
Wavelength Range- 190 - 1100nm
Spectral Bandwidth- 2nm (5nm, 1nm optional)
Detector- Silicon photo-diode
Photometric Accuracy- 0.5%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)
UV-Visible Split Beam
Optical System- Split Beam
Wavelength Range- 190-1100nm
Spectral Bandwidth- 2nm fixed slit
Detector- Silicon photodiode
Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004Abs (0.5 - 1A), ± 0.3%T(0 - 100%T)
Optical System- Split Beam
Wavelength Range- 190-1100nm
Spectral Bandwidth- 0.5, 1, 2, 5nm (variable slit)
Detector- Silicon photodiode
Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004Abs (0.5 - 1A), ± 0.3%T(0 - 100%T)
Visible Spectrophotometer
Optical System- Single Beam
Wavelength Range- 320 - 1100nm
Spectral Bandwidth- 2.0nm (5nm, 1nm optional)
Detector- Silicon photodiode
Photometric Accuracy- ± 0.5%T (0 - 100%T), ± 0.002A (0 - 0.5A), ± 0.004A (0.5A - 1A)
Wavelength Range- 320 ~ 1100nm
Spectral Bandwidth- 5nm (1nm, 2nm, 4nm optional)
Detector- Silicon photo-diode
Photometric Accuracy- 0.5%T