Spectrophotometer


Atomic Absorption Spectrophotometer


  • Wavelength Range–190-900nm
  • Background Correction– The S-H background correction capability at 1.8A better than 30 times.
  • Lamp Turret– 6
     

  • Wavelength Range–190-900nm
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times.
  • Lamp Turret–4

  • Wavelength Range–190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times.
  • Lamp Turret–2 lamps are powered simulataneously(one preheated).

  • Wavelength Range– 190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times.The S-H    background correction capability at 1.8A is better than 30 times.
  • Lamp Turret– 6-lamp turret (Two high performance HCLs can be mounted on the turret to increase the sensitivity)

  • Wavelength Range– 190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. T
  • Lamp Number– 4 lamps.

 


  • Wavelength Range– 190-900nm.
  • Zeeman background correction technology
  • Lamp Turret– Automatic 8 x 2 lamp turret (Two high performance hollow cathode lamps can be mounted on       each turret)
  • Flame mode- 0.2, 0.4, 0.8, 1.6mm
  • Graphite furnace mode- 0.2, 0.4, 1.2mm

  • Wavelength Range– 190-900nm
  • Background Correction– Deuterium lamp 1.0 Abs
  • Burner– Titanium alloy burner


Atomic Emission Spectrophotometer


  • Spectrum range  175-450 nm
  • Maximum number of channel – 36
  • Power supply – AC 220v ±10% 50 Hz
  • Input power – 1.0 kVA


Atomic Fluorescence Spectrophotometer


  • Techniques with independent intellectual property.
  • Environmental protection type Atomic Fluorescence Spectrophotometer with "High efficiency Hg-elimination Technique" can decontaminate Hg pollution in lab environment efficiently and protect analyst’s health.
  • Determination of Hg, As, Sb, Bi, Se, Te, Pb, Sn, Ge, Zn and Cd.
  • Quartz atomizer with "full-ceramics infrared heating temperature control" technique has super long lifetime.
  • “Low-temperature atomic Argon-Hydrogen flame auto-ignition" can improve the analysis sensitivity of elements to be determined and reduce memory effect in large degree.


FTIR Spectrometers


  • Spectral Range – 7800cm-1 to 400cm-1
  • Resolution – Better than 0.85cm-1
  • Scanning Speed – 0.2 cm-1/s ~ 0.25cm-1/s automatically optimized for detector type or manually adjustable for specific application
  • Detector – DTGS; Optional: MCT

  • Spectral Range – 7800cm-1 to 400cm-1
  • Resolution – Better than 0.5cm-1
  • Scanning Speed – 0.2 cm-1/s ~ 0.25cm-1/s automatically optimized for detector type or manually adjustable for specific application
  • Detector – DTGS; Optional: MCT


UV-Visible Double Beam Spectrophotometer


  • Optical System- Double Beam
  • Wavelength Range- 190 ~1100 nm
  • Spectral Bandwidth- 2 nm (5nm, 4nm, 1nm, 0.5nm optional)
  • Detector- Silicon photo diode
  • Photometric Accuracy- ±0.3%T (0~100%T); ±0.002A (0~1A)
     

  • Optical System- Double Beam
  • Wavelength Range- 190~900nm
  • Spectral Bandwidth- 0.1nm, 0.2nm, 0.5nm, 1.0nm, 2.0nm
  • Detector- Photomultiplier
  • Photometric Accuracy- ± 0.3%T (0~100%T), ± 0.002A
         (0~0.5A), ± 0.004A    (0.5A~1A)

  • Optical System- Double Beam
  • Wavelength Range- 190 - 1100nm
  • Spectral Bandwidth- 2nm (fixed slit)
  • Detector- Silicon photodiode
  • Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)

  • Optical System- Double Beam
  • Wavelength Range- 190 - 1100nm
  • Spectral Bandwidth- 0.5, 1, 2, 5nm (Variable slit)
  • Detector- Silicon photodiode
  • Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)

  • Optical System- Double Beam
  • Wavelength Range- 190 - 900nm
  • Spectral Bandwidth- 0.5, 1, 2, 5nm (Variable slit)
  • Detector- Silicon photodiode
  • Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)


UV-Visible Single Beam Spectrophotometer


  • Optical System- Single Beam
  • Wavelength Range- 190 - 1100nm
  • Spectral Bandwidth- 2nm (5nm, 4nm, 1nm, 0.5nm optional)
  • Detector- Silicon photodiode
  • Photometric Accuracy- 0.3%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)

  • Optical System- Single Beam
  • Wavelength Range- 190 - 1100nm
  • Spectral Bandwidth- 2nm (5nm, 1nm optional)
  • Detector- Silicon photo-diode
  • Photometric Accuracy- 0.5%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)

  • Optical System- Single Beam
  • Wavelength Range- 190 - 1100nm
  • Spectral Bandwidth- 2nm (5nm, 1nm optional)
  • Detector- Silicon photo-diode
  • Photometric Accuracy- 0.5%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)


UV-Visible Split Beam


  • Optical System- Split Beam
  • Wavelength Range- 190-1100nm
  • Spectral Bandwidth- 2nm fixed slit
  • Detector- Silicon photodiode
  • Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004Abs (0.5 - 1A), ± 0.3%T(0 - 100%T)

  • Optical System- Split Beam
  • Wavelength Range- 190-1100nm
  • Spectral Bandwidth- 0.5, 1, 2, 5nm (variable slit)
  • Detector- Silicon photodiode
  • Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004Abs (0.5 - 1A), ± 0.3%T(0 - 100%T)


Visible Spectrophotometer


  • Optical System- Single Beam
  • Wavelength Range- 320 - 1100nm
  • Spectral Bandwidth- 2.0nm (5nm, 1nm optional)
  • Detector- Silicon photodiode
  • Photometric Accuracy- ± 0.5%T (0 - 100%T), ± 0.002A (0 - 0.5A), ± 0.004A (0.5A - 1A)

  •  Wavelength Range- 320 ~ 1100nm
  • Spectral Bandwidth- 5nm (1nm, 2nm, 4nm optional)
  • Detector- Silicon photo-diode
  • Photometric Accuracy- 0.5%T
 

 


Spectrophotometer   
UV Visible Spectrophotometers   
Visible Spectrophotometer   
Double beam Spectrophotometer   
Split beam Spectrophotometer   
UV VIS Split Beam Spectrophotometers   
UV VIS Double Beam Spectrophotometers   
Spectroscopy.   

Make your search complete by depending on Labnics for the standard spectrophotometers. We offer a range of visible, UV Visible, UV VIS split beam and UV VIS double beam spectrophotometers that are most appropriate and dynamic in yielding accurate results.